Vent venligst...
Varen er tilføjet indkøbskurven. Se indkøbskurv her

CISCO NEXUS 7010 BUNDLE CHASSIS SUP1

Forsiden Kommunikation Netværkstilbehør CISCO NEXUS 7010 BUNDLE CHASSIS SUP1
CISCO NEXUS 7010 BUNDLE CHASSIS SUP1 (N7K-C7010-BUN)

CISCO NEXUS 7010 BUNDLE CHASSIS SUP1

Varenr.:
N7K-C7010-BUN
EAN:
0882658298332
  • Produkt Diverse
359.782,-
449.727,50 inkl. moms
Antal:
Beskrivelse

Cisco Nexus 7000 Series Chassis

The Cisco Nexus™ 7000 Series Switches combine the highest levels of scalability with operational flexibility.

The Cisco Nexus 7000 Series Switches comprise a modular data center-class product line designed for highly scalable 10 Gigabit Ethernet networks with a fabric architecture that scales beyond 15 terabits per second (Tbps). Designed to meet the requirements of the most mission-critical data centers, it delivers continuous system operation and virtualized, pervasive services. The Cisco Nexus 7000 Series is based on a proven operating system, with enhanced features to deliver real-time system upgrades with exceptional manageability and serviceability. Its innovative design is purpose built to support end-to-end data center connectivity, consolidating IP, storage, and interprocess communication (IPC) networks onto a single Ethernet fabric.

The first in the next generation of switch platforms, the Cisco Nexus 7000 Series provides integrated resilience combined with features optimized specifically for the data center for availability, reliability, scalability, and ease of management.

Features and Benefits

Coupled with the Cisco® NX-OS Software, the Cisco Nexus 7000 Series delivers a rich set of features with nonstop operation. Two chassis form factors are available.
• Front-to-back airflow with 10 front-accessed vertical module slots and an integrated cable management system, facilitates installation, operation, and cooling in both new and existing facilities.
• 18 front-accessed module slots with side-to-side airflow in a compact horizontal form factor with purpose-built integrated cable management eases operations and reduces complexity.
• Designed for reliability and maximum availability, all interface and supervisor modules are accessible from the front, and the redundant power supplies, fan trays, and fabric modules are all accessible completely from the rear to ensure that cabling is not disrupted during maintenance.
• The system uses dual dedicated supervisor modules; a scalable, fully distributed fabric architecture composed of up to five rear-mounted fabric modules combined with the chassis midplane delivers up to 230 Gbps per slot for 7 Tbps of forwarding capacity in the 10-slot form factor and 15 Tbps in the 18-slot form factor.
• The midplane design supports flexible technology upgrades as your needs change and provides ongoing investment protection.

Cisco Nexus 7000 Series 10-Slot Chassis
• The Cisco Nexus 7000 Series 10-slot chassis with up to eight I/O module slots supports up to 256 10 Gigabit Ethernet or 384 Gigabit Ethernet ports, meeting the demands of large deployments.
• Front-to-back airflow helps ensure that use of the Cisco Nexus 7000 Series 10-slot chassis addresses the requirement for hot-aisle and cold-aisle deployments without additional complexity.
• The system uses dual system and fabric fan trays for cooling. Each fan tray is redundant and composed of independent variable-speed fans that automatically adjust to the ambient temperature, helping reduce power consumption in well-managed facilities while providing optimum operation of the switch. The system design increases cooling efficiency and provides redundancy capabilities, allowing hot swapping without affecting the system; if either a single fan or a complete fan tray fails, the system continues to operate without a significant degradation in cooling capacity.
• The integrated cable management system is designed for fully configured systems cabling to be groomed either to a single side or to both sides for maximum flexibility without obstructing any important components, which eases maintenance even when the system is fully cabled.
• The system supports an optional air filter to help ensure clean air flow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.
• A series of LEDs at the top of the chassis provides a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.
• The cable management cover and optional front module doors provide protection from accidental interference with both the cabling and modules installed in the system. The transparent front door allows observation of cabling and module indicator and status lights.

Cisco Nexus 7000 Series 18-Slot Chassis
• The Cisco Nexus 7000 Series 18-slot chassis with up to 16 I/O module slots supports up to 512 10 Gigabit Ethernet or 768 Gigabit Ethernet ports, meeting the demands of the largest deployments.
• Side-to-side airflow increases the system density within a 25 rack-unit (25RU) footprint, optimizing the use of rack space. The optimized density provides more than 16RU of free space in a standard 42RU rack for cable management and patching systems.
• The integrated cable management system is designed to support the cabling requirements of a fully configured system to either or both sides of the switch, allowing maximum flexibility. All system components can easily be removed with the cabling in place, providing ease of maintenance tasks with minimal disruption.
• A series of LEDs at the top of the chassis provides a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.
• The purpose-built optional front module door provides protection from accidental interference with both the cabling and modules installed in the system. The transparent front door allows easy observation of cabling and module indicators and status lights without any need to open the doors, reducing the likelihood of faults caused by human interference. The door supports a dual-opening capability for flexible operation and cable installation while fitted. The door can be completely removed easily for both initial cabling and day-to-day management of the system.
• Independent variable-speed system and fabric fans provide efficient cooling capacity to the entire system. Fan tray redundancy features help ensure reliability of the system and support for hot swapping of fan trays.

Energy Efficient Design
The Cisco Nexus 7000 Series uses power supplies that are up to 90 percent efficient, so less power is wasted as heat and more power is available for the system to use than with typical power supplies.
The fan modules in the chassis adjust to compensate for changing thermal characteristics. At the lower speeds, they use less power.
Consolidation of multiple switches in the Cisco Nexus 7000 Series is enabled by the powerful combination of high density and performance, support for device virtualization, and comprehensive reliability and availability features. This consolidation increases the power efficiency by reducing wasted power from multiple partially loaded and inflexible systems.

Product Specifications

Item

Specification

 

Cisco Nexus 7000 Series 10 Slot Chassis

Cisco Nexus 7000 Series 18

Product compatibility

Supports all Cisco Nexus 7000 Series modules

Supports all Cisco Nexus 7000 Series modules

Software compatibility

Cisco NX-OS Software Release 4.0 or later (minimum requirement)

Cisco NX-OS Software Release 4.1 or later (minimum requirement)

Options

• Air filter
• Lockable front module doors

Lockable front module door

Performance

480 million packets per second (Mpps) (IPv4 unicast) in combination with supervisor and fabric modules

960 (Mpps) (IPv4 unicast) in combination with supervisor and fabric modules

Reliability and availability

• Mean time between failure (MTBF): 264,552 hours
• Online insertion and removal (OIR) of all redundant components: Supervisor, fabric, power supply, and fan trays
• MTBF: 206,038 hours
• OIR of all redundant components: supervisor, fabric, power supply, and fan trays

MIBs

Supports Simple Network Management Protocol (SNMP) Versions 3, 2c, and 1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Network management

Cisco Data Center Network Manager (DCNM) 4.0

Cisco DCNM 4.1

Programming interfaces

• XML
• Scriptable command-line interface (CLI)
• Cisco DCNM 4.0 Web Services
• XML
• Scriptable CLI
• Cisco DCNM 4.1 Web Services

Physical specifications

• Usable rack space: 21RUs
• 10-slot chassis: 2 dedicated supervisors and 8 I/O modules
• 5 fabric module slots
• 3 power supply slots
• Dimensions (H x W x D): 36.5 x 17.3 x 33.1 in. (92.7 x 43.9 x 84.1 cm)
• Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
• Unit is rack mountable in a standard 19-inch (482.6mm) Electronic Industries Alliance (EIA) rack
• Weight
• Chassis only: 200 lb (90 kg)
• Fully configured: 500 lb (227 kg)
• Power requirements: 110 to 240 VAC
• Usable rack space: 25RUs
• 18-slot chassis: 2 dedicated supervisors and 16 I/O modules
• 5 fabric module slots
• 4 power supply slots
• Dimensions (H x W x D): 43.5 x 17.3 x 33.1 in. (110.5 x 43.9 x 84.1 cm)
• Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
• Unit is rack mountable in a standard 19-inch (482.6mm) EIA rack
• Weight
• Chassis only: 187 lb (85 kg)
• Fully configured: 684 lb (311 kg)
• Power requirements: 110 to 240 VAC

Mean time between failure (MTBF)

• 264,652 hours
• 206,038 hours

Environmental specifications

• Airflow direction: Bottom front of chassis to top back
• Operating temperature: 32 to 104°F (0 to 40°C)
• Operational relative humidity: 5 to 90%, noncondensing
• Operating altitude: -500 to 13,123 ft (agency certified 0 to 6500 ft)
• Seismic: Zone 4 per GR63
• Floor loading: 190 lb per sq ft
• Operational vibration
• GR63, Section 5.4.2
• ETS 300 019-1-3, Class 3.1, Section 5.5
• Storage altitude: 1000 to 30,000 ft
• Storage temperature: -40 to 158°F (-40 to 70°C)
• Storage relative humidity: 5 to 95%, noncondensing
• Heat dissipation: Maximum -12,000W per chassis (actual dissipation will be lower, depending on the chassis configuration)
• Airflow direction: Side to side
• Operating temperature: 32 to 104°F (0 to 40°C)
• Operational relative humidity: 5 to 90%, noncondensing
• Operating altitude: -500 to 13,123 ft (agency certified 0 to 6500 ft)
• Seismic: Zone 4 per GR63
• Floor loading: 190 lb per sq ft
• Operational vibration
• GR63, Section 5.4.2
• ETS 300 019-1-3, Class 3.1, Section 5.5
• Storage altitude: 1000 to 30,000 ft
• Storage temperature: -40 to 158°F (-40 to 70°C)
• Storage relative humidity: 5 to 95%, noncondensing
• Heat dissipation: Maximum -18,000W per chassis (actual dissipation will be lower, depending on the chassis configuration)

Regulatory compliance

• EMC compliance
• FCC Part 15 (CFR 47) (USA) Class A
• ICES-003 (Canada) Class A
• EN55022 (Europe) Class A
• CISPR22 (International) Class A
• AS/NZS CISPR22 (Australia and New Zealand) Class A
• VCCI (Japan) Class A
• KN22 (Korea) Class A
• CNS13438 (Taiwan) Class A
• CISPR24
• EN55024
• EN50082-1
• EN61000-3-2
• EN61000-3-3
• EN61000-6-1
• EN300 386

Environmental standards

• NEBS criteria levels
• SR-3580 NEBS Level 3 (GR-63-CORE, issue 3, and GR-1089-CORE, issue 4)
• Verizon NEBS compliance
• Telecommunications Carrier Group (TCG) Checklist
• Qwest NEBS requirements
• Telecommunications Carrier Group (TCG) Checklist
• ATT NEBS requirements
• ATT TP76200 level 3 and TCG Checklist
• ETSI
• ETSI 300 019-1-1, Class 1.2 Storage
• ETSI 300 019-1-2, Class 2.3 Transportation
• ETSI 300 019-1-3, Class 3.2 Stationary Use
• Reduction of Hazardous Substances (ROHS) 5

Safety

• UL/CSA/IEC/EN 60950-1
• AS/NZS 60950

Warranty

Cisco Nexus 7000 Series Switches come with the standard Cisco 1-Year Limited Hardware Warranty

Ordering Information

Product Name

Part Number

System

Cisco Nexus 7000 Series 10-Slot chassis including Fan Trays, No Power Supply

Cisco Nexus 7000 Series 10-Slot chassis including Fan Trays, No Power Supply

N7K-C7010

N7K-C7010=

Cisco Nexus 7000 Series-10-Slot System Fan Tray Spare

N7K-C7010-FAN-S=

Cisco Nexus 7000 Series-10-Slot Fabric Fan Tray Spare

N7K-C7010-FAN-F=

Cisco Nexus 7000 Series 18-Slot chassis including Fan Trays, No Power Supply

Cisco Nexus 7000 Series 18-Slot chassis No Fan Trays, No Power Supply

N7K-C7018

N7K-C7018=

Cisco Nexus 7000 Series-18-Slot Fan Tray Spare

N7K-C7018-FAN=

Cisco Nexus 7000 Series 10-Slot Accessories

Cisco Nexus 7010-Air Filter

N7K-C7010-AFLT=

Cisco Nexus 7000-Rack Mount Kit

N7K-RMK=

Cisco Nexus 7010-EMI Inlet Screen Kit

N7K-C7010-EMI-SC=

Cisco Nexus 7010 Front Door Top Section-including Cable Management Kit

N7K-C7010-FD-TOP=

Cisco Nexus 7010 Front Door-Kit

N7K-C7010-FD-MB=

Cisco Nexus 7000 Bottom Support Kit

N7K-BSK=

Cisco Nexus 7010 Fabric Module Blank

N7K-FAB-BLANK=

Cisco Nexus 7000 Series 18-Slot Accessories

Cisco Nexus 7018 Rack Mount Kit

N7K-C7018-RMK=

Cisco Nexus 7018 Front Top Section and Cable Mgmt Kit

N7K-C7018-CAB-TOP=

Cisco Nexus 7018 Front Door Kit

N7K-C7018-FD-MB

Cisco Nexus 7018 Bottom Support Kit

N7K-C7018-BSK

Cisco Nexus 7018 Fabric Module Blank

N7K-C7018-F-BLANK=

Blank Panel Covers

Cisco Nexus 7000 Series Supervisor Blank Slot Cover

N7K-SUP-BLANK=

Cisco Nexus 7000 Series Module Blank Slot Cover

N7K-MODULE-BLANK=

Cisco Nexus 7010 Chassis Power Supply Blank Slot Cover

N7K-PS-BLANK=

Cisco Nexus 7018 Chassis Power Supply Blank Slot Cover with Handle

N7K-PS-BLANK-H=

Cisco Nexus 7000 Series Network Clock Card Blank

N7K-CLK-BLANK=


Cisco Nexus 7000 Series Supervisor Module

The Cisco® Nexus 7000 Series Supervisor Module scales the control plane and data plane services for the Cisco Nexus 7000 Series system in scalable data center networks.

The Cisco Nexus 7000 Series Switches comprise a modular data center-class product line designed for highly scalable 10 Gigabit Ethernet networks with a fabric architecture that scales beyond 15 terabits per second (Tbps). Designed to meet the requirements of the most mission-critical data centers, it delivers continuous system operation and virtualized, pervasive services. The Cisco Nexus 7000 Series is based on a proven operating system, with enhanced features to deliver real-time system upgrades with exceptional manageability and serviceability. Its innovative design is purpose built to support end-to-end data center connectivity, consolidating IP, storage, and interprocess communication (IPC) networks onto a single Ethernet fabric.

The Cisco Nexus 7000 Series Supervisor Module is designed to deliver scalable control plane and management functions for the Cisco Nexus 7000 Series chassis. It is based on a dual core processor that scales the control plane by harnessing the flexibility and power of the dual cores. The supervisors control the Layer 2 and 3 services, redundancy capabilities, configuration management, status monitoring, power and environmental management, and more. It provides centralized arbitration to the system fabric for all line cards. The fully distributed forwarding architecture allows the supervisor to support transparent upgrades to higher forwarding capacity-capable I/O and fabric modules. The supervisor incorporates an innovative dedicated connectivity management processor (CMP) to support remote management and troubleshooting of the complete system. Two supervisors are required for a fully redundant system, with one supervisor module running as the active device and the other in hot standby mode, providing exceptional high-availability features in data center-class products.

The Cisco Nexus 7000 Series Supervisor Module delivers a comprehensive set of features to address the needs of the most demanding data center deployments.
• Continuous system operation
– Active and standby supervisor
– Segmented and redundant out-of-band provisioning and management paths
– Virtualization of the management plane
– Integrated diagnostics and protocol decoding with an embedded control plane packet analyzer
• Upgradeable architecture
– Fully decoupled control plane and data plane with no hardware forwarding on the module
– Distributed forwarding architecture, allowing independent upgrades of the supervisor and fabric
– Unified Fabric ready
– Transparent upgrade capacity and capability; designed to support 40 Gigabit and 100 Gigabit Ethernet
• Superior operational efficiency
– System locator and beacon LEDs for simplified operations
– Dedicated out-of-band management processor for `lights out' management

Product Specifications

Item

Specifications

Product compatibility

Cisco Nexus 7000 Series Switches

Software compatibility

Cisco NX-OS Software Release 4.0 or later (minimum)

Cards, ports and slots

Two supervisor modules required per system for high availability

Interfaces

• Supervisor management port: 10/100/1000-Mbps Ethernet port, support for inline encryption through MAC security (IEEE 802.1AE)
• CMP management port: 10/100/1000-Mbps Ethernet port
• Console serial port: RJ45 connector
• Auxiliary serial port: RJ45 connector
• 3 USB ports: 2 host and 1 device port for peripheral devices

Memory

• DRAM: 4 GB
• Flash memory: 2 GB
• NVRAM: 2 Mb battery backup

Options

• Removable storage; 2 external type II compact flash memory slots:
• Log (8 GB)
• Expansion (2 GB)

Reliability and availability

• Mean time between failure (MTBF): 99,491 hours
• Online insertion and removal (OIR)

MIBs

Simple Network Management Protocol (SNMP) Versions 3, 2c and 1 supported; see Cisco NX-OS Software release notes for details of specific MIB support

Network management

• Cisco Data Center Network Manager (DCNM) 4.0
• Cisco VFrame Data Center 1.2

Programming interfaces

• Extensible Markup Language (XML)
• Scriptable command-line interface (CLI)
• Cisco DCNM 4.0 Web Services

Physical specifications

• Occupies one supervisor slot in a Cisco Nexus 7000 Series chassis
• Dimensions (H x W x D): 1.2 x 15.3 x 21.9 in. (3.0 x 38.9 x 55.6 cm)
• Weight: 10 lb (4.5 kg)

Environmental conditions

• Operating temperature: 32 to 104°F (0 to 40°C)
• Operational relative humidity: 5 to 90%, noncondensing
• Storage temperature: -40 to 158°F (-40 to 70°C)
• Storage relative humidity: 5 to 95%, noncondensing

Regulatory compliance

• EMC compliance
• FCC Part 15 (CFR 47) (USA) Class A
• ICES-003 (Canada) Class A
• EN55022 (Europe) Class A
• CISPR22 (International) Class A
• AS/NZS CISPR22 (Australia and New Zealand) Class A
• VCCI (Japan) Class A
• KN22 (Korea) Class A
• CNS13438 (Taiwan) Class A
• CISPR24
• EN55024
• EN50082-1
• EN61000-3-2
• EN61000-3-3
• EN61000-6-1
• EN300 386

Environmental standards

• NEBS criteria levels
• SR-3580 NEBS Level 3 (GR-63-CORE, issue 3, and GR-1089-CORE, issue 4)
• Verizon NEBS compliance
• Telecommunications Carrier Group (TCG) Checklist
• Qwest NEBS requirements
• Telecommunications Carrier Group (TCG) Checklist
• ATT NEBS requirements
• ATT TP76200 level 3 and TCG Checklist
• ETSI
• ETSI 300 019-1-1, Class 1.2 Storage
• ETSI 300 019-1-2, Class 2.3 Transportation
• ETSI 300 019-1-3, Class 3.2 Stationary Use

Safety

• UL/CSA/IEC/EN 60950-1
• AS/NZS 60950

Warranty

Cisco Nexus 7000 Series Switches come with the standard Cisco 1-Year Limited Hardware Warranty

Ordering Information

Product Name

Part Number

Cisco Nexus 7000 Series Supervisor Module, Includes External 8Gb flash

Cisco Nexus 7000 Series Supervisor Module, Includes External 8Gb flash Spare

N7K-SUP1

N7K-SUP1=

Cisco Nexus 7000 - Compact Flash Memory - 2 GB (Expansion Flash)

Cisco Nexus 7000 - Compact Flash Memory - 2 GB (Expansion Flash) Spare

N7K-CPF-2GB

N7K-CPF-2GB=

Cisco Nexus 7000 - Compact Flash Memory - 8 GB (Log Flash) Spare

N7K-CPF-8GB=


Cisco Nexus 7000 Fabric Module

The Cisco® Nexus™ 7000 Series Switches comprise a modular data center-class product line designed for highly scalable 10 Gigabit Ethernet networks with a fabric architecture that scales beyond 15 terabits per second (Tbps). Designed to meet the requirements of the most mission-critical data centers, it delivers continuous system operation and virtualized, pervasive services. The Cisco Nexus 7000 Series is based on a proven operating system, with enhanced features to deliver real-time system upgrades with no service disruption together with exceptional manageability and serviceability. Its innovative design is purpose built to support end-to-end data center connectivity, consolidating IP, storage, and interprocess communication (IPC) networks onto a single Ethernet fabric.

The Cisco Nexus 7000 Fabric Modules for the Cisco Nexus 7000 Series Chassis are separate fabric modules that provide parallel fabric channels to each I/O and supervisor module slot. Up to five simultaneously active fabric modules work together delivering up to 230 Gbps per slot. Through the parallel forwarding architecture, a system capacity of more than 8 Tbps is achieved with the five fabric modules. The fabric module provides the central switching element for fully distributed forwarding on the I/O modules.

Features and Benefits

Switch fabric scalability is made possible through the support of from one to five concurrently active fabric modules for increased performance as your needs grow. All fabric modules are connected to all module slots. The addition of each fabric module increases the bandwidth to all module slots up to the system limit of five modules. The architecture supports lossless fabric failover, with the remaining fabric modules load balancing the bandwidth to all the I/O module slots, helping ensure graceful degradation.

The combination of the Cisco Nexus 7000 Fabric Module and the supervisor and I/O modules supports virtual output queuing (VoQ) and credit-based arbitration to the crossbar switch to increase performance of the distributed forwarding system. VoQ and credit-based arbitration facilitate fair sharing of resources when a speed mismatch or contention for an uplink interface exists. The fabric architecture also enables future support for lossless Ethernet and unified I/O capabilities.

Product Specifications

Item

Specification

 

Cisco Nexus 7000 10-Slot Fabric Module

Cisco Nexus 7000 18-Slot Fabric Module

Product compatibility

Supported in the Cisco Nexus 7000 Series 10-Slot Chassis

Supported in the Cisco Nexus 7000 Series 18-Slot Chassis

Software compatibility

Cisco® NX-OS Software Release 4.0 (minimum requirement)

Cisco NX-OS Software Release 4.1(2) (minimum requirement)

Performance

46 Gbps per slot per fabric

46 Gbps per slot per fabric

Reliability and availability

• Mean time between failure (MTBF): 651,072 hours
• Online insertion and removal (OIR) hot swap
• MTBF: 423,846 hours
• OIR hot swap

MIBs

Supports Simple Network Management Protocol (SNMP) Versions 3, 2c, and 1 (see the Cisco NX-OS Software release notes for details about specific MIB support)

Supports SNMPv3, v2c, and v1 (see the Cisco NX-OS Software release notes for details about specific MIB support)

Network management

Cisco Data Center Network Manager (DCNM) 4.0

Cisco DCNM 4.1

Programming interfaces

• XML
• Scriptable command-line interface (CLI)
• Cisco DCNM 4.0 Web Services
• XML
• Scriptable CLI
• Cisco DCNM 4.1 Web Services

Physical specifications

• Occupies one fabric module slot in a Cisco Nexus 7000 Series 10-Slot Chassis
• Dimensions (H x W x D): 1.733 x 14.93 x 7.33 in. (4.4 x 37.92 x 18.62 cm)
• Weight: 4 lb (1.8 kg)
• Occupies one fabric module slot in a Cisco Nexus 7000 Series 18-Slot Chassis
• Dimensions (H x W x D): 14.93 x 1.733 x 7.33 in. (37.6 x 4.4 x 18.62 cm)
• Weight: 7.5 lb (3.4 kg)

Environmental conditions

• Operating temperature: 32 to 104°F (0 to 40°C)
• Operational relative humidity: 5 to 90%, noncondensing
• Storage temperature: -40F to 158°F (-40 to 70°C)
• Storage relative humidity: 5 to 95%, noncondensing

Regulatory compliance

• EMC compliance
• FCC Part 15 (CFR 47) (USA) Class A
• ICES-003 (Canada) Class A
• EN55022 (Europe) Class A
• CISPR22 (International) Class A
• AS/NZS CISPR22 (Australia and New Zealand) Class A
• VCCI (Japan) Class A
• KN22 (Korea) Class A
• CNS13438 (Taiwan) Class A
• CISPR24
• EN55024
• EN50082-1
• EN61000-3-2
• EN61000-3-3
• EN61000-6-1
• EN300 386

Environmental standards

• NEBS criteria levels
• SR-3580 NEBS Level 3 (GR-63-CORE, issue 3, and GR-1089-CORE, issue 4)
• Verizon NEBS compliance
• Telecommunications Carrier Group (TCG) Checklist
• Qwest NEBS requirements
• Telecommunications Carrier Group (TCG) Checklist
• ATT NEBS requirements
• ATT TP76200 level 3 and TCG Checklist
• ETSI
• ETSI 300 019-1-1, Class 1.2 Storage
• ETSI 300 019-1-2, Class 2.3 Transportation
• ETSI 300 019-1-3, Class 3.2 Stationary Use

Safety

• UL/CSA/IEC/EN 60950-1
• AS/NZS 60950

Warranty

Cisco Nexus 7000 Series Switches come with the standard Cisco 1-Year Limited Hardware Warranty

Ordering Information

Product Name

Part Number

Cisco Nexus 7000 10-Slot Chassis 46Gbps/Slot Fabric Module (and spare)

N7K-C7010-FAB-1

N7K-C7010-FAB-1=

Cisco Nexus 7000 18-Slot Chassis 46Gbps/Slot Fabric Module (and spare)

N7K-C7018-FAB-1

N7K-C7018-FAB-1=

Selvom vi gør vort bedste for at give fyldestgørende information, så er billederne kun vejledende, og selve varen er ikke nødvendigvis 100% identisk med det viste billede. Produkter kan være vist med ekstraudstyr der ikke er inkluderet eller i andre form- og farvevarianter. Hvis der er forskel mellem produktoverskrift, beskrivelse og billede, så er det produktoverskriften som gælder. Hvis du er i tvivl, så kontakt os gerne. Vi tager forbehold for trykfejl, ændring af priser og specifikationer uden varsel.